8 channels.
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A.
Output: 0~10000.
18 point terminal.
Directly connected to the CT sensor, saving wiring and space of the CT input module.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc A8GT-C100BS Price. .
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored
A8GT-C100BS
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor A8GT-C100BS Price.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost .
Set the CT sensor type (input range) for each channel.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting A8GT-C100BS Price.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will suddenly change .
By detecting the transient peak current at this time, the fault of the equipment can be diagnosed.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value).
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 11kw.
SLD converter rated current: 63A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation.
((rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station MITSUBISHI A8GT-C100BS.
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same timme,, used in the control of the external machine MITSUBISHI A8GT-C100BS.
No external PID controller is used to control the external machine, so the system cost can be reduced.
A8GT-C100BS Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A8GT-C100BS&select=5