Function: CPU module (internal service power supply).
Input and output points: 32 points.
Power supply capacity (DC5V power): 1100mA.
Power supply capacity (DC24V service power supply): 600mA.
Input / output mode: DC input (drain / source) / transistor (source).
Input points: 32 points.
Output points: 32 points FR-PU07 Price.
The new expansion module is more convenient!
Pioneer products with advanced built-in functions and rich extensibility
FR-PU07
FX5U built-in analog, communication, high speed input and output,
By extending the board and adapter can be easily extended system.
In addition, through the high speed system bus,
Can maximize the role of the built-in intelligent functions of the expansion device FR-PU07 Price.
Input type: DC input, positive common end .
Input points: 8 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
External connection: 3 wire.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input FR-PU07 Price. Description: SI/QSI type optical fiber cable with (combination of 2 sets of use), the maximum number of connections: 3, the longest transmission distance: 500M (SI) /1000m (QSI) .
Spare 5 products for different purposes.
Thin waterproof type relay hub.
Extension of star type wiring and main line length, waterproof structure.
Spring clip terminal type relay hub.
Star type wiring, length of the main line, spring clamping terminal table type.
Relay appliance (T branch) unit.
Extension of T type branch and trunk length.
Relay unit in light.
In the presence of interference in the environment of the wiring, the length of the trunk line.
Relay unit in space light.
Communication between linear moving bodies. Transmission line unit for MELSECNET/MINI (-S3) twisted pair data link.
Loop: twisted pair I/F.
Remote station: twisted pair line I/F.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBIISHI PLC program simulaation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee prrogram MITSUBISHI FR-PU07 MITSUBISHI FR-PU07.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
FR-PU07 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FR-PU07&select=5