Axis of control: 2.
Operation cycle: 0.444ms, 0.888ms, 1.777ms, 3.555ms.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Boot time (operation cycle 0.444ms, 1 axes): 0.7ms.
Servo amplifier connection mode: SSCNET III /H.
Inter station distance (max): 100m.
External wiring connection mode: 40 pin connector HC-KFS13 Price.
Linear interpolation: 2 axes.
Arc interpolation: 2 axes.
Motion control by simple programming
HC-KFS13
Can be realized through the software gear, shaft, transmission, cam action.
The most suitable for milling spiral line interpolation.
Normal start, high speed start, multi axis simultaneous start.
High precision ON/OFF pulse time measurement HC-KFS13 Price.
IQ-R MELSEC series of simple movement module, positioning module, high-speed counter module for intelligent function module,
High speed and high precision motion control, position control and position detection can be carried out by simple programming .
The simple motion module has the same operation convenience as the positioning module,
Like motion controller for synchronous control, cam control and other advanced control HC-KFS13 Price.
Can be connected to the servo system dedicated to support high-speed synchronous network /H III SSCNET servo amplifier .
Positioning control (sealant / adhesive coating equipment etc.).
Synchronous control / electronic cam control (pick and place machine, packing machine, etc.).
Speed / torque control (stamping machine, die casting machine, etc.).
Speed / position control switching (production of semiconductor chips, etc.). MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 5.5kw.
SLD converter rated current: 34A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation.
((rectifier separation tyype will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station MITSUBISHI HC-KFS13.
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same timme,, used in the control of the external machine MITSUBISHI HC-KFS13.
No external PID controller is used to control the external machine, so the system cost can be reduced.
HC-KFS13 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HC-KFS13&select=5