Power supply: 110mA DC5V (PLC internal power supply), 90mA DC24V (external power supply).
Analog input points: 4 points.
Voltage input: DC-10~10V.
Current input: DC-20~20mA, 4~20mA.
Weight: 0.2kg.
Dimensions: 55 x 90 x 87.
Voltage input and current input of 4 channels can be carried out,
Each channel can be specified as a current input or voltage input MITSUBISHI HF-KN23BJ-S100.
Built in digital filter function and peak hold function, etc
HF-KN23BJ-S100,
Achieved a high speed of 500 AD S/ch conversion.
FX3U-4AD can connect FX3GA/FX3G, FX3GE, FX3U series.
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-IPS-5V. Enter points: 64 points MITSUBISHI HF-KN23BJ-S100.
Voltage: DC12/24V.
Current: 3/7mA.
Response time: 10ms.
32 points / a common end .
Negative utility.
37 pin connector.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear MITSUBISHI HF-KN23BJ-S100.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive .
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The coontents of the compponent image register are changed with the change of the execution of the program HF-KN23BJ-S100.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to thhe adoption of centralized sampling HF-KN23BJ-S100.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.