The input and output module installation number: 5.
Can install module: MELSEC-Q series module.
DIN guide rail mounting adapter type: Q6DIN2.
Size (H) * (44.1mm) * (W) * (D): * 245mm * 98mm.
Substrate module for mounting various modules of MELSEC-Q series.
Extended use of Q series expansion substrates in the following extensions MITSUBISHI HF-SE202. "Power: 75kw.
Voltage: 200V.
Sine wave filter.
The voltage and current of the motor can be adjusted to a sine wave
HF-SE202
The sine wave filter is installed to the output terminal of the inverter.
Applicable to FR-A820-03800 (75K) above and FR-A840-02160 (75K) and above frequency converter.
Sine wave filter is equivalent to the operational characteristics of the sine wave power driver, can provide the following benefits MITSUBISHI HF-SE202.
Low noise.
No surge current.
Reduce motor loss (standard motor). Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output."X 10BASE-T/100BASE-T 1 channel.
No need to use PC to meet all the recording needs of the high-speed data recorder module MITSUBISHI HF-SE202.
High speed, simple, low cost, the accuracy of data records beyond the past .
Can be used to guide the form of a simple set of high speed data recorder module configuration tool",
And display the collected data with the trend chart,
Help to carry out data analysis, etc. the recording data display / analysis tool "LogViewer GX"".
By accumulating all kinds of data in the production process,
Not only can help improve the quality of products, reduce production costs, but also for the optimization of the system,
Contribute to the construction of an efficient production site. "Input points: 32 points.
Voltage: DC12/24V.
Current: 4/10mA.
Response time: 10ms.
8 points / a common end.
Cathode common.
38 point terminal station.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The coontents of thhe component image register are changed with the change of the execution of the program HF-SE202.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to thhe adoption of centralized sampling HF-SE202.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
HF-SE202 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HF-SE202&select=5