For A6TBXE/A6TBY36E/A6TBX54E/A6TBY54E/A6TBX70E (common cathode; source) long 2m.Motor series: ultra low inertia, low power.
Rated output power: 0.1kw.
Rated speed: 3000r/min.
Whether to bring the brakes: with.
Shaft end: Standard (straight).
Protection level: IP55 does not include the shaft part and the connector MITSUBISHI HG-SR502J.
Features: ultra low inertia is suitable for high frequency operation.
Application examples: the insertion device, the assembly machine
HG-SR502J Input points: 32 points.
Input voltage: DC24V.
Enter the public side of the way: 32 points / public.
Output form: transistor output (source).
Output points: 32 points.
Rated output voltage: DC12 ~ 24V MITSUBISHI HG-SR502J.
Max load current: 0.1A/1 point.
Protection function: have
Output common way: 32 point / common .
Input / output occupied points: 32 points (I/O distribution: input and output mixed 32 points).
External wiring connection: 40 pin connector two.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system MITSUBISHI HG-SR502J.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged .
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability. Ethernet network module 10BASE-T/10BASE5
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state oof tthe machine movement,
Make maintenance work efficiency also greatly improved HG-SR502J HG-SR502J.
Q series PLC in the use of CC-Link function better,
And easier to use.