MITSUBISHI general purpose AC servo amplifier MELSERVO-J2-Super series.
Rated output: 0.4kw.
Built in program operation.
Voltage: single phase AC100V.
Super function, excellent performance.
High performance CPU integration, greatly improve product responsiveness.
Due to the application of high performance CPU, so that the response can be greatly improved MITSUBISHI QS061P-A1.
Speed loop frequency response increased to more than 550HZ
QS061P-A1
MR-J2-Super series is the best device for high speed positioning applications.
Easy adjustment.
Model adaptive control / advanced real time automatic tuning. Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V MITSUBISHI QS061P-A1.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing .
Output points: 16 points.
Output voltage: DC24V/AC240V, 2A/1 point, 4A/ common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side.
50 point terminal station.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI QS061P-A1.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signaal transmissioon device, brake signal and fan fault signal QS061P-A1.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee ssystem controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points QS061P-A1.
QS061P-A1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=QS061P-A1&select=5