Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 3 points (common universal).
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485 OMRON .
Event input: 1 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility
70069-1014 SCL10(D)
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15 OMRON . 2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications .
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set OMRON .
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication .
Combined temperature control device through component communication. Type: Flat Cable.
Terminal Block: Terminal block with M3 screws.
Connector: Flat Cable Connectors*1.
No. of poles: 34.
Simplifies Connector and terminal,
block replacement, and requires less,
in-panel wiring.
Mount to DIN Track or via screws.
MIL Flat Cable Connectors and Multi-pole, Square,
Connectors are standard.
Terminal blocks available with either M3 or M3.5 screws.
Connecting Cables for Programmable Controllers,
available (sold separately). Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displayinng the status of the Temperatuure Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV OMRON 70069-1014 SCL10(D).
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs OMRON 70069-1014 SCL10(D).
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
70069-1014 SCL10(D) Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=70069-1014 SCL10(D)&select=5