LK Automation Limited
Home >> Price >> OMRON >> OMRON 44507-1611 MA16DP10C6 44507-1611 MA16DP10C6
Brand sort

OMRON 44507-1611 MA16DP10C6 44507-1611 MA16DP10C6

No PHOTO
Country: JAPAN
Name:
Market price: U.S.$ 0
(The following are the market open price not sales price!)
OMRON 44507-1611 MA16DP10C6
Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage OMRON 44507-1611 MA16DP10C6.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase 44507-1611 MA16DP10C6
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation OMRON 44507-1611 MA16DP10C6.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions . Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Unit type: CJ1 Special I/O Units OMRON 44507-1611 MA16DP10C6.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 .
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions .
Series cconnection is possible only with the MSF4800A 44507-1611 MA16DP10C6.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt CCurtain functions 44507-1611 MA16DP10C6.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
44507-1611 MA16DP10C6 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=44507-1611 MA16DP10C6&select=5


...more relevant model market price >>>>
Related products
Related download