E3JK-R32 regression reflection type,
E3JK direct current mode: mode; ON,
Miniature amplifier built-in type photoelectric switchType: rectangle.
Screen mode: no segmentation.
Output: DPDT.
Power supply voltage: DC24V.
Contact type: standard load (AC250V, 3A; DC30V, 3A).
Operation: instantaneous action (auto reset) OMRON 60568-0100 CBL-47TXD-10M.
Operation Department color: Blue (using yellow and green LED).
In the touch and the ability to protect than OMRON''s previous models have improved
60568-0100 CBL-47TXD-10M
The micro volume design of 23mm is realized.
Micro design and unique combination of soft sensing.
LED has five colors (red, yellow, green, white, and blue) OMRON 60568-0100 CBL-47TXD-10M.
Built in basic switch improves touch.
Built in basic switches in the previous model based on the OMRON to improve the protection .
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Sealed pin plunger.
Cable length : 3 m OMRON 60568-0100 CBL-47TXD-10M.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard) .
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Name: AC Input Unit.
Rated input voltage: 200/240 VAC.
Refer to Safety Precautions for All Solid State Relays.
AC Input Unit Enabling AC Operation.
Connects to a maximum of two G3PA-VD Relays. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / manual, RUUN/STOP, alarm), interactive display PV/SV 60568-0100 CBL-47TXD-10M.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation 60568-0100 CBL-47TXD-10M.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
60568-0100 CBL-47TXD-10M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=60568-0100 CBL-47TXD-10M&select=5