Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 2 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector A273UHCPU.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input
A273UHCPU Connector set for
HC-SFS121B; 201B; 301B.
HC-SFS202B; 352B; 502B; 702B; 2024B; 5024B; 3524B; 7024B.
353B; HC-SFS203B.
302B; HC-LFS202B.
HA-LFS601B; 801B; 12K1B; 6014B; 8014B; 12K14B.
HA-LFS701MB; 11K1MB; 15K1MB; 701M4B; 11K1M4B; 15K1M4B A273UHCPU.
15K2B; HA-LFS11K2B. Motor series: super low inertia, medium power .
Rated output power: 2.0kw.
Rated speed: 3000r/min.
Whether to take the brake: No.
Shaft keyway: (open slot).
Protection level: IP65 (IP67).
Features: ultra low inertia is suitable for high frequency operation.
Application example: ultra high frequency transmission machinery.
High resolution encoder 131072p/rev (17 bit) A273UHCPU.
The encoder with high resolution ensures excellent performance and stability at low speed .
All motor dimensions are the same as before and all are compatible with the wiring.
Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 8A/1 public end.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
20 point terminal station.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoidd valve can be known,
A ssingle coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 outtput, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI A273UHCPU MITSUBISHI A273UHCPU.
A273UHCPU Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A273UHCPU&select=5