MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 1.0kw.
Interface type: CC-Link communication type (built-in positioning function).
Power specification: three phase AC200V.
Positioning operation by setting position and rotational speed data in the positioning table and receiving the start signal from the main controller QJ71LP21G.
The setting of the position and speed of the positioning table, as well as the start and stop operation can be completed through CC-Link communication
QJ71LP21G
By using the MR-J3-D01 extension IO unit, the DI/O instruction can be used to select and locate the table.
(CC-Link can not be used for MR-J3-D01 communications) QJ71LP21G.
With built-in positioning function of the servo amplifier, can be set through the CC-Link communications and speed data . (corresponding to the CC-Link version: Ver.1.10)
Can be achieved through the CC-Link communications to start, stop and monitoring and other operations.
Serial communication reduce wiring.
Distributed servo control system can be built by CC-Link communication QJ71LP21G.
The parameters of unit MR-PRU03 (optional) the parameter setting, operation and monitoring more convenient .
The servo amplifier can be used for speed control operation.
When the two stations are occupied, the speed can be set directly by the remote register. MELSECNET/MINI (-S3) data link system, A2C system transfer converter.
Twisted pair cable -GI optical fiber cable.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBIISHI PLC program simulatiion debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee prrogram MITSUBISHI QJ71LP21G MITSUBISHI QJ71LP21G.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
QJ71LP21G Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=QJ71LP21G&select=5