Type: rectangle.
Screen mode: no segmentation.
Using voltage: DC24V.
Operation Department color: Red / green.
Micro design, the length of the body is only 23mm.
LED has five colors (red, yellow, green, white, and blue).
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient OMRON E2A-S08KN04-M5-B1. Size: 96 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
E2A-S08KN04-M5-B1
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type OMRON E2A-S08KN04-M5-B1.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points .
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm OMRON E2A-S08KN04-M5-B1.
The upper panel and the front panel are equipped with tool ports .
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. E32-D25YR type: standard type; soft (new standard),
Specialty: plane shape (small) side,
Bending radius (mm): R; R1.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsMeasuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvolltages and,
undervolttages E2A-S08KN04-M5-B1.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssuppported E2A-S08KN04-M5-B1.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
E2A-S08KN04-M5-B1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2A-S08KN04-M5-B1&select=5