Terminal (Wire connection): Screw terminal.
Classification: Standard.
Latching lever (Test switch): Yes.
Rated input voltage: DC, 24V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel OMRON F3SJ-A0935P20-TS.
Realized opening and closing ability with one pole 6 A slim shape
F3SJ-A0935P20-TS
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location) OMRON F3SJ-A0935P20-TS.
Screw terminal is also stocked to meet the screw type needs .
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Appearance: Square/Projection type A22-C.
Output: SPST-NC + SPST-NC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green);
W (white); A (blue); B (black) OMRON F3SJ-A0935P20-TS.
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring) .
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Operating modes: Power OFF Delay.
Supply voltage: 200 to 240 VAC.
Control output: Contact output: SPDT.
H3DK-H: L Series (time range: 1.0 to 120 s).
Set two time ranges with each Timer, from 0.1 to 12 seconds for,
the S Series and from 1.0 to 120 seconds for the L Series. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation F3SJ-A0935P20-TS.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions F3SJ-A0935P20-TS. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.