LK Automation Limited
Home >> Price >> OMRON >> G2R-1A-E-ASI AC100 OMRON G2R-1A-E-ASI AC100
Brand sort

G2R-1A-E-ASI AC100 OMRON G2R-1A-E-ASI AC100

No PHOTO
Country: JAPAN
Name:
Price: 0
OMRON G2R-1A-E-ASI AC100
Type: 1C contact type.
Shape: round.
Terminal shape: solder terminal.
Action: alternate.
Display mode: do not display.
Operation Department color: light gray.
Large capacity compact type push button switch.
Can also be used as a power switch with a large capacity cut.
Can be switched from micro load (minimum applicable load 1mA DC5V) to large capacity load OMRON G2R-1A-E-ASI AC100. The main body: terminal type, temperature input type G2R-1A-E-ASI AC100
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points OMRON G2R-1A-E-ASI AC100.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function .
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement OMRON G2R-1A-E-ASI AC100.
E5CN-U (insert type) add analog input and current output type .
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or resistance thermometer.
Auxiliary outputs: None.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 . G2R-1A-E-ASI AC100.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannuaal, RUN/STOP, and alarms) and the PV or SV G2R-1A-E-ASI AC100.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
G2R-1A-E-ASI AC100 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=G2R-1A-E-ASI AC100&select=5


...more relevant model market price >>>>
Related products
Related download