Actuator: Roller plunger.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement OMRON .
Standardized gold-clad contacts provide high contact reliability
E2B-M30LN30-WZ-C1 5M
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Control supply voltage: 110/220 VAC; Without voltage fluctuation compensation OMRON .
Operating current: 1 to 2 A.
Accurate Detection of Heater Element .
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out OMRON .
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters .
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Detected voltage: AC.
Compact, Economical Plug-in Type Voltage.
Sensing Relay.
DPDT output contacts expand the application of the Sensor to,
wide-ranging fields including control, alarms, and indication.
Voltage control is possible in the same easy manner as electro,
magnetic relays, as the output relay of the sensor can be driven,
directly with a detection signal.
Wide voltage setting range with fine setting capability. C500-DA Special I/O Unit Analog Output C500-DA101.
Output: 4 pts.
Specification: +1~+5V、0~+10V、4~20mA.Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance perfformance .
The connection methhod can be selected from a screw terminal and a PUSH-IN fastening terminal OMRON E2B-M30LN30-WZ-C1 5M.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsiion Village (sold separately) connected to the computer after,
No power connection can be set OMRON E2B-M30LN30-WZ-C1 5M.
It can be easily set by CS-Thermo (sold separately).
E2B-M30LN30-WZ-C1 5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2B-M30LN30-WZ-C1 5M&select=5