E32-T333-S5 type: special beam type; ultra small / small diameter beam,
Specialty: Phi 0.25 casing,
Open diameter: 0.125,
Shape / detection distance (mm): 12; 10; 6 (4),
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: 0.125 (0.005),
Fiber element for meeting diversified needsTerminal type: Exposed-lead Models E52-CA35AY D=1.6 NETU 1M Price.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 20 cm
E52-CA35AY D=1.6 NETU 1M
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E52-CA35AY D=1.6 NETU 1M Price.
Ideal for the thermal input devices of Temperature Controllers .
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Sensor type and wiring: 3-wire DC PNP/2-wire DC 1-4.
Actuator wiring: Actuator wiring 3-4 E52-CA35AY D=1.6 NETU 1M Price.
No. of ports: 4.
No. of I/O: 8.
Simple Wiring of Sensor Actuators.
Greatly reduce wiring in combination with the Smartclick XS5 .
Insert the connector and turn 1/8 of a turn to lock the connectors.
Higher rated current to enable output applications.
Use previous M12 screw connectors. Type: 1a1b welding terminal.
Shape: round.
Type: small load.
Action: instantaneous action (auto recovery).
With light: LED with light.
Using voltage: DC12V.
Operation Department color: green.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (VVer .4.3 CX-Thermo) makes the proceess of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output OMRON E52-CA35AY D=1.6 NETU 1M.
Through the infrared port can be carried out from the frronnt of the communication OMRON E52-CA35AY D=1.6 NETU 1M.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
E52-CA35AY D=1.6 NETU 1M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E52-CA35AY D=1.6 NETU 1M&select=5