Fitting materials: Stainless steel(SUS304).
Count: 1 .
Accessories: Description, Phillips screw Nut plat;
Material, Stainless steel Stainless steel;
Count, 2, 1.
Applicable sensor (mounting pitch on sensor side): ZX1-LD50, ZX1-LD100 @@.
Page: Dimensions, 16.
Size: M12 (Brass); Double; Shielded (See note 2 OMRON G6C-2114P-US-U DC24. ).
Sensing distance: 8 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short
G6C-2114P-US-U DC24
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase) OMRON G6C-2114P-US-U DC24.
Output specifications: Two transistor outputs .
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control OMRON G6C-2114P-US-U DC24.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Thermocouple type: J (IC).
Heat resistance: General use.
Outer packing: all ethylene outer wrapping (waterproof).
Compensating wire length: 1 m.
A variety of high precision temperature sensor series.
On the basis of the previous M3 screw,
An additional rod like terminal corresponding to the reduced wiring working hours.
A temperature sensor is used as a thermal sensor for a thermostat.
According to the temperature, place, the surrounding environment to be measured.
Products with various shapes, shapes, lengths and terminals.
Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, connvenient to check the sttate of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV G6C-2114P-US-U DC24.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput G6C-2114P-US-U DC24.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
G6C-2114P-US-U DC24 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=G6C-2114P-US-U DC24&select=5