Unit type: CS1 Basic I/O Units.
Product name: DC Input Unit.
Specifications: 24 VDC, 6 mA,
32 inputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3,YES, @@2, YES;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,@@3,YES,
@@2, YES; CS1 Long distance Expansion Rack,
Yes; SYSMAC BUS Slave Rack, No E2V-X15C1 5M.
Words required: (I/O bits: CIO 0000 to CIO 0319), 2 words.
Current consumption: 5V system, 0
E2V-X15C1 5M15A;
26 V system, --.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Shape: dip solder terminal.
Pole number: 16.
Pole pole number: 1 E2V-X15C1 5M.
Minimum packing unit: 110.
Printed board connector core, MIL specification standard .
Through the use of new productivity design, high reliability and low price synchronization.
A box type plug (XG4C) which is convenient for saving space is provided in the province.
A press type plug (XG4E) capable of using the relay is provided.
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type E2V-X15C1 5M.
(XG2) combined use of various types of packaging can be achieved .
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No. E103202 File) certified products. Optical cable(H-PCF cable).Aluminum and Iron Both.
Detectable from Long Distances. Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furtherr performance improvement OMRON E2V-X15C1 5M.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee ddisplay PV/SV OMRON E2V-X15C1 5M.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
E2V-X15C1 5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2V-X15C1 5M&select=5