Magnetic Latching Version of G2A Ideal for.
Sequence Control.
Double-winding latch system with continuous rating.
Terminals pulled from the respective junctions between the,
built-in diodes and set and reset coils allow the built-in diodes to,
be externally connected for coil surge absorption.
Excellent vibration/shock resistance with minimal secular,
decrease in latching power OMRON D4GL-4CFG-A.
Easy monitoring of ON/OFF operation due to the built-in,
operation indicator mechanism
D4GL-4CFG-A
Same outline dimensions as the standard models of G2A. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control OMRON D4GL-4CFG-A.
Input specifications: Two current inputs,
(for either single phase or threephase) .
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control OMRON D4GL-4CFG-A.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Models: OVGR (64).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electriic side / internnal tributaries D4GL-4CFG-A.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiinee the direction of the sudden drop in the voltage to 0 of the short-circuit accident D4GL-4CFG-A.
2 stage cross terminal stand with cover with convenient wiring.
D4GL-4CFG-A Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4GL-4CFG-A&select=5