Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC OMRON D4NH-2FBC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability
D4NH-2FBC
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. I/O capacity/Mountable Units(Expansion Racks): 1, 280 points/40 Units (3 Expansion Racks max OMRON D4NH-2FBC. ).
CJ1G-CPU44H Program capacity: 30K steps .
CPU Unit CJ1G-CPU44H Data memory capacity: 64K words(DM: 32K words, EM: 32K words × 1 bank).Unit type: CJ1 CPU Bus Unit.
Product Name: Ethernet Unit.
Specifications:Communications cable,
100Base-TX; Communications functions,
FINS communications service(TCP/IP, UDP/IP),
FTP server functions, socket services,
mail transmission service,
mail reception (remote command receive),
automatic adjustment of PLC''s built-in clock,
server/host name specifications;
nits per CPU Unit: 4 OMRON D4NH-2FBC.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.37A; 24V,--.
Standards: UC1, N, L, CE.
Organically Connect the Production,
Site and Management Select the required,
communications services according to,
application needs to flexibly integrate,
PLCs with an Ethernet information network. Output type: Transistor sourcing.
Inputs points: 12 points.
Outputs points: 8 points.Power ratings: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Output current: 20 A Peak current 30 A (200 VAC).
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UUL Class 2 Outtput standards D4NH-2FBC.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) D4NH-2FBC.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
D4NH-2FBC Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4NH-2FBC&select=5