Ontology: basic.
Size: 48 x 96mm.
Type: control valve control type (input).
Control mode: 1 channel position ratio control.
Output (control / transfer) points: relay output (open 1 points, 1 points) + current (transfer) 1.
Output (SUB) points: 4 points.
Event input points: -.
Serial communication: RS-485 OMRON E5CN-HR2 AC100-240.
High speed, high precision and multiple input and output universal digital regulator,
Liquid crystal display device with high visibility 5 bit and 3 line
E5CN-HR2 AC100-240
The high speed sampling period is suitable for the operation of high speed response.
With a backlight liquid crystal display and the 3 display, can display the current value, the target value, the amount of operation OMRON E5CN-HR2 AC100-240.
1 digital controller can be multi point control / series control / proportion control .
Standard is equipped with a variety of computing functions.
Equipped with DeviceNet communication function.
Data setting and data monitoring can be performed by means of a communication program. Release key type: Special release key.
Indicator: Green OMRON E5CN-HR2 AC100-240.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO .
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 40 A at 24 to 240 VAC.
Rated input voltage: 5 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimuum design of heat sink E5CN-HR2 AC100-240.
Mounting possible via screws or via DIN track.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2.)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply witth VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load E5CN-HR2 AC100-240.
Certified by UL, CSA, and VDE (reinforced insulation).
E5CN-HR2 AC100-240 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E5CN-HR2 AC100-240&select=5