Terminal type: Exposed-lead Models.
Protective tubing diameter D: 4.8 dia.
Protective tubing length L: 35cm.
Lead wire type: Heat resistive.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E6A2-CW3E 100P/R 0.5M.
Ideal for the thermal input devices of Temperature Controllers
E6A2-CW3E 100P/R 0.5M
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Type: Welding / wire type, M3 screw mounting OMRON E6A2-CW3E 100P/R 0.5M.
Drive rod: rod type Shibai leaf.
Terminal specifications: with wire, the right side of the lead .
Contact specifications: 1b.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1 OMRON E6A2-CW3E 100P/R 0.5M. 4mm).
Without harmful substances to the environment, the lead type has also been lead-free . Actuator: Roller lever: R38.
Item: High-sensitivity.
Connector shape: Threaded (M12).
Built-in switch type: Airtight.
Voltage: DC.
Wiring locations: NC + NO 4 core.
Connector pin No: NC 1 2; NO 3 4.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches.
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models. Time specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation E6A2-CW3E 100P/R 0.5M.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions E6A2-CW3E 100P/R 0.5M. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
E6A2-CW3E 100P/R 0.5M Operation manual/Instructions/Model selection sample download link: