Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function OMRON EE-SX1035.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved
EE-SX1035
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0 OMRON EE-SX1035. 01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms .
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay) OMRON EE-SX1035.
Setting the program settings that can perform flexible contact output .
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Safety outputs *3: Instantaneous, 3(Semiconductor);
OFF-delayed*2, 2 (Semiconductor).
Auxiliary outputs *4: 2(Semiconductor).
Logical AND connection: Inputs, 1(Semiconductor); Outputs, 1(Semiconductor).
No. of input channels: 1 or 2 channels.
Max. OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control system setup.
Solid-state outputs (excluding Expansion Units).
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set.
-Two logical AND connection inputs. Appearance: M30.
Sensing distance: 10 mm.
Connection method: M12 Connector Models.
Cable specifications: --.
Operation mode : NC .
Pin arrangement: 1: +V, 3: 0 V, 2: Control output.
Applicable connector code: D.
Model: NPN output.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E.
Standard Sensors for detecting ferroous metals .
Wide array of variations EE-SX1035. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC annd sensing surface made of material that resists,
cutting oil EE-SX1035.
Useful to help prevent disconnection.
Cable protector provided as a standard feature.
EE-SX1035 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=EE-SX1035&select=5