Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector,
PNP outputs (pulses).
No. of unit numbers allocated: 2 OMRON D4GL-1FFA-A4.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE
D4GL-1FFA-A4
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output OMRON D4GL-1FFA-A4. Operating: Appearance, 40-dia. head Medium Push-lock Turn-reset With EMO, Indication; Contact Configuration, 3NC (1NC + 1NC + 1NC) .
Color of cap: Red.
Install in 22-dia. or 25-dia. Panel Cutout.
Direct opening mechanism to open the circuit when the contact welds.
Safety lock mechanism prevents operating errors.
Easy mounting and removal of Switch Blocks using a lever.
Mount three Switch Units in series to improve wiring efficiency,
(with non-lighted Switch Units, three Units can be mounted for,
multiple contacts) OMRON D4GL-1FFA-A4.
Finger protection mechanism on Switch Unit provided as a,
standard feature.
Install using either round, or forked crimp terminals.
Oil-resistant to IP65 (non-lighted models)/IP65 (lighted models),
A lock plate is provided as a standard feature to ensure that the,
control box and switch are not easily separated. Unit classification: CJ1 Special I/O Units.
Product name: ProcessInput Units,
(Isolated-type Thermocouple Input Units).
Input points: 2 inputs.
Signal range selection:
Set separately for each input.
Signal range: Thermocouple:
B, E, J, K, L, N, R, S, T, U,
WRe5-26, PLII DC voltage: ±100 mV.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000.
Accuracy at ambient temperature of 25°C:
Standard accuracy: ±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers aallocated: 1 .
Current consumption: 5V, 0 D4GL-1FFA-A4.18A; 24V, 0.06A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) D4GL-1FFA-A4.
All inputs are isolated.
D4GL-1FFA-A4 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4GL-1FFA-A4&select=5