Specifications: I/O, NPN (input: + common, output: - common), 16 inputs/16 outputs.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring OMRON E5AN-R3FL-N AC100-240.
User boards attach easily to the DRT2-@D32BV(-1) using screws
E5AN-R3FL-N AC100-240 Type: 3 wire, shielded.
Shape: 4.
Detection range: 0.8mm.
Connection mode: lead type (2m).
Wire specification: PVC (oil resistant).
Action mode NO.
NPN output OMRON E5AN-R3FL-N AC100-240.
Proximity sensors for preferred world top performance and quality.
Standard type of magnetic metal detection .
Rich variety.
According to the conditions to choose the most suitable models.
Anti interference function of different frequency range models.
Has excellent environmental performance.
Standard wire material for oil resistant PVC.
Test face using cutting oil material OMRON E5AN-R3FL-N AC100-240.
Standard wire jacket. Type: rectangle.
Screen mode: level 2.
Output: DPDT.
Power supply voltage: DC24V .
Contact type: standard load (AC250V, 3A; DC30V, 3A).
Operation: instantaneous action (auto reset).
Operating above color: red.
Color: yellow.
In the touch and the ability to protect than OMRON''s previous models have improved.
The micro volume design of 23mm is realized.
Micro design and unique combination of soft sensing.
LED has five colors (red, yellow, green, white, and blue).
Built in basic switch improves touch.
Built in basic switches in the previous model based on the OMRON to improve the protection.
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient. Appearance: there are F4 shell, R2 shell.
Circuit structure and open circuit mode: single contact 1C, voltage, no voltage, DC circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit element time to adjust the degree 0.25-0.5-1-2-3-4-5-6-7-8-9-10,
12 nominal action time to adjust the scale of 10300% over current, 10s plus or minus 5%,
700% over current, 1.52s plus or minus 7%; instantaneous elements, nominal action time 200% over current 40ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: closed circuit, 110V 5A L/R=0ms1000 DC220V times, 10A L/R=0ms1000 DC times;
30W (DC 110V 1A closed, L/R=25ms1000), 80VA (AC 220V 1A) cos with =0.1 1000.
Contact: AC110V, 7.5A, COS with =0.4; (AC250V 825VA)
DC24V, 5A, L/R=7ms (maximum 50W time DC125V).
Automatic experiment: No.
Display: start display (LED), after the time display (LED).
Output display, trip (R phase and T phase) manual reset type, instant manual reset type.
Excitation surge current suppression (fuzzy inference): -.
Quality: about 1.3KG (R2 shell), about 1.8kg (F1 shell), about 3.3kg (D2 shell).
External: Mount Searl N1.5.
Static type over current relay K2CA-D type, attention to the protection of the coordination of static type OCR.
The prootection coordination betwween OCR and MCCB is simple E5AN-R3FL-N AC100-240.
1 sets of three-phase protection, can save space and manpower.
Compared with the plate movement start display, through time display, make maintenance and inspection becomes simple.
The display oof the accident occurrence phase is used to facilitate the inspection after the accident E5AN-R3FL-N AC100-240.
Reduce the consumption of VA, reduce the burden of converter.
E5AN-R3FL-N AC100-240 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E5AN-R3FL-N AC100-240&select=5