Number of elements: 3.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuit input).
Applicable motor: 0.75 kW (4.8 A), 200 to 220 VAC.
Soft-start Function Starts Motors Smoothly,
and Economically.
The soft-start function allows a smooth startup of motors by,
holding down the starting current, and functions like an inverter
E6B2-CWZ3E 500P/R 0.5M
Comply with UL, CSA, IEC, and JEM requirements.
Mount with screws or to DIN tracks.
Compact monoblock construction (W: 80 × H: 100 × D: 100 mm).
with a heat sink.
Snubber circuit and varistor are built-in OMRON E6B2-CWZ3E 500P/R 0.5M.
Operation indicator. Size: 48 x 96mm.
Control output 1: relay output.
Control output 2: relay output .
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: -.
Event input: 4 points.
Remote SP input: - OMRON E6B2-CWZ3E 500P/R 0.5M.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use .
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from tthe start of operation E6B2-CWZ3E 500P/R 0.5M.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions E6B2-CWZ3E 500P/R 0.5M. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
E6B2-CWZ3E 500P/R 0.5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E6B2-CWZ3E 500P/R 0.5M&select=5