Supply voltage: 24, 100 to 120, 200 to 230 VAC;
12, 24, 48, 100 to 110, 125 VDC.
Time-limit contact: DPDT.
Long-time range model(0.1 min to 10 h).
Miniature Timer with Multiple Time.
Ranges and Multiple Operating Modes.
Minimizes stock.
Pin configuration compatible with MY Power Relay.
Standard multiple operating modes and multiple time ranges E6H-CWZ6C 2000P/R 0.5M.
Conforms to EN 61812-1 and IEC 60664-1 for Low Voltage,
and EMC Directives
E6H-CWZ6C 2000P/R 0.5M Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling E6H-CWZ6C 2000P/R 0.5M.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater .
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved E6H-CWZ6C 2000P/R 0.5M.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, connvenient to check the state of thhe thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV OMRON E6H-CWZ6C 2000P/R 0.5M.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput OMRON E6H-CWZ6C 2000P/R 0.5M.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
E6H-CWZ6C 2000P/R 0.5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E6H-CWZ6C 2000P/R 0.5M&select=5