Unit type: CS1 Special I/O Units.
name: Position control unit.
Specifications: Control method/Control,
output interface, Open-loop control by,
pulse train output/Open-collector output;
Number of control axes, 2 axis.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: U, C, N, L, CE OMRON 3G8F7-SLK21-E.
High-speed, High-precision,
positioning with 1, 2, or 4 axes
3G8F7-SLK21-E
Versatile functions and superb,
performance enable the construction,
of compact, high-performance machines.
With its ultra-compact size of 31×90mm,
(W×H),this highly space-efficient Position,
Control Unit(PCU) enables up to 4 axes,
of motor control.Unit type: CS1 CPU Bus Unit.
Product name:Ethernet Units OMRON 3G8F7-SLK21-E.
Specifications: Communi cations cable,
100BASE TX Cable; Communications functions,
FINS communications service(TCP/IP and UDP/IP),
FTP server function, socket service,
mail send service, mail reception,
(remote command reception),
auto-adjustment of PLC''s internal clock,
and server host name specification;
Duplexing, Not supported;
Units per CPU Unit, 4 Units.
No. of unit numbers allocated: 1 OMRON 3G8F7-SLK21-E.
Current consumption: 5V, 0.38A; 26V, --.
Standards: UC1, N, L, CE.
Organically Connect the Production,
Site and Management.
Select the required communications,
services according to application needs,
to flexibly integrate PLCs with an,
Ethernet information network OMRON . Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit OMRON .
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0 OMRON . 16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems 3G8F7-SLK21-E.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems OMRON 3G8F7-SLK21-E.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.