Input points: 16 points.
Input voltage and current: 6mA DC24V.
Response time: 0/0.1/0.2/0.4/0.6/1ms.
16 point /1 a public side.
Common anode.
18 point terminal station.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings MITSUBISHI A6TBX70. And there is no need to select the cable, the straight line and the cross line can be used
A6TBX70
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location MITSUBISHI A6TBX70.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control MITSUBISHI A6TBX70.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password MITSUBISHI Connector / terminal conversion module.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users MITSUBISHI Connector / terminal conversion module.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.SD memory card 16GB.
Can be used on the Q24DHCPCPU-V.
Can be used on the Q24DHCPCPU-LS.
Can be used on the QnUDVCPU.AC input: 32 points MITSUBISHI Connector / terminal conversion module.
Rated current and voltage: AC100 ~ 120V, 10mA (AC100V, 60Hz).
Response time: 25ms.
Input form: 1 points, 32 public ends.
External wiring connections: 38 terminals (terminals sold separately).
Replacement model: AX11.Control axis: maximum 32 axes.
Teaching operation function: No.
To stop the speed control function at the specified location.
The servo motor can rotate at a predetermined speed,
After startingg the specified location to stop the instruction,
Can be set in advance to stop the location A6TBX70.
You can change the speed by changing the value of the options at the time of the operation,
You can also change the acceleration / decelleration time MITSUBISHI A6TBX70.
Phase compensation function.
The mixed function of virtual mode and real mode.
Smooth clutch linear acceleration / deceleration function.