A6WU MITSUBISHI A6WU

Brand: MITSUBISHI
Name: ROM program unit
Model: A6WU
Ontology CPU installation to P-ROM program device.

Input points: 16 points.
Voltage: DC48V.
Current: 4mA.
Response time: 10ms.
8 points / a common end.
Positive / negative.
20 point terminal station.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read MITSUBISHI A6WU A6WU
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three MITSUBISHI A6WU.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive MITSUBISHI A6WU.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC MITSUBISHI ROM program unit.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation MITSUBISHI ROM program unit.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. Data communication line module (optical cable) Master / local station for A3VTS multiplex system
MITSUBISHI PLC detection, fault diagnosis and diisplay and other procedures MITSUBISHI ROM program unit A6WU.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
MITSUBISHI PLC protection and chain procedures.
Protection aand chain is an indispensable part of the program, must be carefully considered MITSUBISHI A6WU.
It can avoid the control logic confusion caused by illegal operations.