LK Automation Limited
Home >> Products >> MITSUBISHI >> A/QnA series PLC >> High function module >> Other high function modules >> AJ71P41 It can avoid the control logic confusion caused by illegal operations MITSUBISHI AJ71P41 SUMINET module

AJ71P41 It can avoid the control logic confusion caused by illegal operations MITSUBISHI AJ71P41 SUMINET module

Brand: MITSUBISHI
Name: SUMINET module
Model: AJ71P41
SUMINET-3200 network.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.

8 channels.
Input: DC-10 ~ 10V/DC4 ~ 20mA.
Output (resolution): -1000 ~ 1000, -2000 ~ 2000.
Transform speed: 2.5ms/1 channel.
47 point terminal station.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CPU MITSUBISHI AJ71P41.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive AJ71P41
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference MITSUBISHI AJ71P41. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light MITSUBISHI AJ71P41.
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal MITSUBISHI SUMINET module.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian MITSUBISHI SUMINET module.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process MITSUBISHI SUMINET module. 2 slots.
Can be installed in the power supply unit for A series units installed QnA/.
Cannot extend.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined accordding to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point AJ71P41.
Taking into account the future adjustment and expansion,
In general should be estimaated on the total number of points plus the amount of spare 20%~30% MITSUBISHI AJ71P41.
The following describes the centralized control system I/O points of the estimate.


...More relevant models >>>>