Name: Screw Terminal Block with Relay Outputs.
16 outputs; Contacts.
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
wiring in the system.
contribute to system size reduction.
helps to detect errors on site.
content of the error.
Name: Repeater Unit.
Specifications: A sub-trunk line can be,
connected downstream,
(for trunk-branch line configuration),
or further branching is enabled downstream,
(for configurations with no wiring restrictions),
in the same way as for a Master Unit.
A Repeater Unit can be used to branch,
the trunk line and increase the,
number of connected Units,
as well as to extend the length of the,
communications line OMRON CRT1-ROS16
CRT1-ROS16
Standards: CE, U, U1, L, N.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection OMRON CRT1-ROS16.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application. Specifications: Inputs, NPN(+ common), 32 inputs.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector OMRON CRT1-ROS16.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring.
User boards attach easily to the DRT2-@D32BV(-1) using screws OMRON CompoNet Gateway Unit for CC-Link. Name: e-CON Connectors.
Specifications: Inputs; 16 inputs; PNP;
With Short-circuit and,
Disconnected Line Detection OMRON CompoNet Gateway Unit for CC-Link.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON CompoNet Gateway Unit for CC-Link.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: I/O, NPN (input: + common, output: - common), 166 inputs/16 outputs CRT1-ROS16.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easiily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring OMRON CRT1-ROS16.
User boards attach easily to the DRT2-@D32BV(-1) using screws.