LK Automation Limited
Home >> Products >> OMRON >> CS1G/CS1H/CS1D/CS1W PLC >> CS1 series PLC CPU high function unit >> CS1W-CLK21-V1 OMRON OMRON CS1W-CLK21-V1

CS1W-CLK21-V1 OMRON OMRON CS1W-CLK21-V1

Brand: OMRON
Name:
Model: CS1W-CLK21-V1
Specifications: Twisted pair.

Name: I/O Control Unit.
Specifications: Applicable systems,
Duplex CPU, Dual I/O Expansion System only;
Duplexing, Supported;
Online Replacement, Supported;
Mounting Backplane, Expansion Backplane;
Connecting Cable, CS1W-CN@@3,
CS-series Connecting Cable.
Current consumption: 5V system, 0.20A;
26V system, -- OMRON CS1W-CLK21-V1.
Standards: UC1, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables CS1W-CLK21-V1 Connection type: Screw - HPCF connector.
Description: Controller link repeater unit (wire to HPCF fibre).Unit type: CS1 Basic I/O Units.
Product name: B7A Interface Unit.
Specifications: 32 inputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No OMRON CS1W-CLK21-V1.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 2 words.
Current consumption: 5V system, 0.09A;
26 V system, --.
Standards: UC1, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control.Unit type: CS1 Special I/O Units.
Product name: Isolated-type Resistance,
Thermometer Input Units (Ni508 OMRON CS1W-CLK21-V1. 4 Ω).
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: INi508 OMRON . 4.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE OMRON .
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON .
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems CS1W-CLK21-V1.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems OMRON CS1W-CLK21-V1.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.


...More relevant models >>>>