Home >> Products >> OMRON >> CS1G/CS1H/CS1D/CS1W PLC >> CS1 series PLC high performance I/O unit >> CS1 series process simulation I/O unit >> CS1W-PDC11 Process Analog I/O Units OMRON CS1W-PDC11 Conversion speed (resolution): 

CS1W-PDC11 Process Analog I/O Units OMRON CS1W-PDC11 Conversion speed (resolution): 

Brand: OMRON
Name: Process Analog I/O Units
Model: CS1W-PDC11
Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.

Unit type: CS1 CPU Bus Unit.
Product Name: MECHATROLINK-II,
compatible Motion Control Unit.
Specifications: Control modes: Position,
speed, or torque control via MECHSTROLINK-II,
Control axes: 32 axes max.
(30 physical axes, 2 virtual axes).
Internal programming language: Special,
motion control language OMRON CS1W-PDC11.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.80A; 26V, -- CS1W-PDC11
Standards: UC1, CE.
Improve Equipment Design Efficiency and,
Shorten Tact Time.
Control Servos for up to 16 axes in a,
motion network with one Position Control,
Unit that supports MECHATROLINK-II .
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association. Unit type: CS1 Special I/O Units OMRON CS1W-PDC11.
name: Position control unit.
Specifications: Control method/Control,
output interface,Open-loop control by,
pulse train output/Line-driver output;
Number of control axes, 4 axis.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.36A; 26V, --.
Standards: U, C, N, L, CE.
High-speed, High-precision,
positioning with 1, 2, or 4 axes.
Versatile functions and superb,
performance enable the construction,
of compact, high-performance machines OMRON CS1W-PDC11.
With its ultra-compact size of 31×90mm,
(W×H),this highly space-efficient Position,
Control Unit(PCU) enables up to 4 axes,
of motor control.Unit type: CS1 Special analog I/O Units OMRON Process Analog I/O Units.
Product name: Analog Output Units.
Specifications: I/O points, 8 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point OMRON Process Analog I/O Units.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.13A; 26V, 0.18A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data OMRON Process Analog I/O Units.
Analog Output Units for converting ,
binary data into analog output signals.Unit type: CS1 CPU Bus Unit.
Product name:EtherNet/IP Unit.
Specifications: Communications,
cable, Shielded twisted-pair(STP),
cable Categories: 100 Ω at 5, 5e;
Communications functions, Tag Data Link,
Functions, Message Communications Functions;
Units per CPU Unit, 8 max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.41A; 26V, --.
Standards: UC1, N, L, CE.
Introducing the New EtherNet/IP Unit.
More Than 180,000 Words of Tag,
Data Link Capacity!
EtherNet/IP is an industrial multivendor,
network that uses Ethernet.
Managed by the ODVA (Open DeeviceNet Vendors,
Association), it has open standards and is used,
with a wide range of industrial devices CS1W-PDC11.
The EtherNet/IP Unit supports tag data links to,
enable sharing data between devices at Ethernet,
nodes and a message sservice for sending and,
receiving data when required OMRON CS1W-PDC11.
The EtherNet/IP Unit supports the same FINS/UDP,
and FINS/TCP functionality as Ethernet Units.