LK Automation Limited
Home >> Products >> OMRON >> Security products >> Safety door switch >> D4NH-4FBC OMRON D4NH-4FBC Safety-door Hinge Switch

D4NH-4FBC OMRON D4NH-4FBC Safety-door Hinge Switch

Brand: OMRON
Name: Safety-door Hinge Switch
Model: D4NH-4FBC
Actuator: Arm lever.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.

Actuator: Arm lever.
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms OMRON D4NH-4FBC.
1NC/1NO, and 2NC. Models with MBB contacts are also available D4NH-4FBC
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. Type: Standard.
Sealing: Flux-tight.
Poles: 6 poles.
Contact configuration: 3PST-NO, 3PST-NC.
Rated voltage: 12, 18, 21, 24, 48, 110 VDC.
Compact, Slim Relays Conforming to,
EN Standards OMRON D4NH-4FBC.
Relays with forcibly guided contacts,
(EN50205 Class A, certified by VDE).
Supports the CE marking of machinery (Machinery Directive).
Helps avoid hazardous machine status when used as part of,
an interlocking circuit.
Four-pole and six-pole Relays are available.
The Relay’s terminal arrangement simplifies PWB pattern design.
Reinforced insulation between inputs and outputs OMRON D4NH-4FBC.
Reinforced insulation between some poles of different polarity. Release key type: Special release key.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+3NC OMRON Safety-door Hinge Switch.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns OMRON Safety-door Hinge Switch.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas OMRON Safety-door Hinge Switch.
IP67 degree of protection. Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key innsertion point D4NH-4FBC.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames OMRON D4NH-4FBC.
The plastic material makes the Slide Key suitable,
for lightweight doors.


...More relevant models >>>>