LK Automation Limited
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> DRT2-ID16TA Transistor Remote I/O Terminals with 3-tier Terminal Blocks A Smart Slave with Relay Outputs and One-step, OMRON DRT2-ID16TA

DRT2-ID16TA Transistor Remote I/O Terminals with 3-tier Terminal Blocks A Smart Slave with Relay Outputs and One-step, OMRON DRT2-ID16TA

Brand: OMRON
Name: Transistor Remote I/O Terminals with 3-tier Terminal Blocks
Model: DRT2-ID16TA
Specifications: Inputs; NPN (+ common);
16 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations.
No relay terminal block terminals required.
Detachable cassette-type circuit sections.

Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON DRT2-ID16TA.
A wide variety of CompoNet Slave Units,
contribute to system size reduction DRT2-ID16TA
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: e-CON Connector Type.
Specifications: Analog inputs;
4 inputs OMRON DRT2-ID16TA.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON DRT2-ID16TA.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Analog output.
I/O points: 4.
I/O connections: Molex connector.
Power supply voltage: 24 VDC.
I/O specification: 0 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V.
Analog Input/Output Units Compatible with MULTIPLE I/O TERMINAL OMRON Transistor Remote I/O Terminals with 3-tier Terminal Blocks.
Input block incorporates connectors that can be easily,
mounted or dismounted OMRON Transistor Remote I/O Terminals with 3-tier Terminal Blocks. (GT1-AD08MX, GT1-DA04MX)
8 or 4 inputs.
4 outputs.
High resolution of 1/6,000.
High conversion speed of 8 ms/8 points or 4 ms/4 points.
DIN track mounting.
Connector model Terminal Block Model.
Specifications: Output, PNP (+ common), 8 points OMRON Transistor Remote I/O Terminals with 3-tier Terminal Blocks.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting.
Functions such as Sensor Power.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabiliities DRT2-ID16TA.
High degree of environmental resistance with dust-proof,
and drip-proofconstruction.
Power supply wiring is not required for input devices.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required foor input devices such as sensors OMRON DRT2-ID16TA.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.


...More relevant models >>>>