LK Automation Limited
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> DRT2-OD08C-1 OMRON DRT2-OD08C-1 I/O connections: Sensor I/O connector Environment-resistive Terminals with Transistors 

DRT2-OD08C-1 OMRON DRT2-OD08C-1 I/O connections: Sensor I/O connector Environment-resistive Terminals with Transistors 

Brand: OMRON
Name: Environment-resistive Terminals with Transistors
Model: DRT2-OD08C-1
Specifications: Output, PNP (+ common), 8 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting.
Functions such as Sensor Power.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
High degree of environmental resistance with dust-proof,
and drip-proofconstruction.
Power supply wiring is not required for input devices.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required for input devices such as sensors.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.

Classification: Analog output.
I/O points: 2 outputs.
Performs Calculations on Analog Values within the Slave Itself.
Also Provides High Resolution at 1/30,000 (Full Scale) and,
Support for a Wide Variety of Data Sampling.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities OMRON DRT2-OD08C-1.
Sampling data can be analyzed internally to provide a low-cost scheduler function DRT2-OD08C-1
Equipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative,
calculation function.
Two I/O points can be allocated to any two of the following values: analog,
input, peak/bottom, top, valley, or rate-of-change OMRON DRT2-OD08C-1. Values without an,
allocated I/O point can be read with message communications. Name: System Units; Turnback Units.
Specifications: Left Turnback Unit,
(Mounts to the left side of Slice I/O,
Terminal. Can supply power to I/O Units.)
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet OMRON DRT2-OD08C-1.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON Environment-resistive Terminals with Transistors  OMRON Environment-resistive Terminals with Transistors . Name: MIL Connectors.
Specifications: Outputs; 16 outputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON Environment-resistive Terminals with Transistors .
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: I/O; NPN (input: + common,
output: - common); 8 inputs/8 outputs.
I/O connections: Sensor connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage:
Supplied from external source for outputs.
Includes Sensor Connector That Conforms to,
Industry Standards And Can Be Used to Connect.
Sensorss with Pre-wired Cables without Using,
Special Tools DRT2-OD08C-1.
Equipped with the standard Smart Slave,
functions that provide powerful.
preventative maintenance and,
troubleshooting capabilities.
Digital I/O Terminal compatible with,,
industry-standard sensor connectors OMRON DRT2-OD08C-1.
Connect sensors easily without special tools.
Reduce time required for wiring.
Load short-circuit detection.