With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
The use of communication adapter cable (sold separately) connected with a computer.
Combined temperature control device through component communication.
Protection tube diameter: screw pitch M6.
Wire length: 1m.
Core line type: K (CA).
Temperature sensing part of temperature controller.
In the application field of packaging molding machine is widely used,
Further strengthened the high cost models.
Easy to install / replace the structure.
With springs, you can use the active part (E52Z-CA1D-40) OMRON E5CC-QX0AUM-000. Case color: Black.
Control output: Current output
E5CC-QX0AUM-000
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- OMRON E5CC-QX0AUM-000.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks OMRON E5CC-QX0AUM-000.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter OMRON Digital temperature controller.
Switch the PV display between three colors OMRON Digital temperature controller.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output OMRON Digital temperature controller.
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Fuurther performance improvement E5CC-QX0AUM-000.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV OMRON E5CC-QX0AUM-000.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.