Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
1 machines to support a variety of sensors.
Interactive display PV/SV.
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia. .
Protective tubing length L: 50cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E5CN-HTV203D-FLK.
Ideal for the thermal input devices of Temperature Controllers
E5CN-HTV203D-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling OMRON E5CN-HTV203D-FLK.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-Q1TC;
Resistance thermometer input, E5GN-Q1P.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function OMRON E5CN-HTV203D-FLK.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks OMRON Programmed temperature controller.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV OMRON Programmed temperature controller.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4 OMRON Programmed temperature controller. 2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Analog(current/voltage).
Alarm output: 2.
option units Mounting: Yes.
Control output: Voltage output(for driving SSR).
Previous mode: None.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models avaiilable with a loop break alarm (LBA) and,
heater short alarm (HS alarm) E5CN-HTV203D-FLK.
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protoocol called Modbus is installed in the models,
with communications OMRON E5CN-HTV203D-FLK.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.