The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Size: 96 x 96mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points OMRON E5CN-Q2HH03T-WFLK.
Communication: RS-485
E5CN-Q2HH03T-WFLK
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports OMRON E5CN-Q2HH03T-WFLK.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications OMRON E5CN-Q2HH03T-WFLK.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication OMRON Foundation type temperature controller.
A new type of proportional control allows you to control the valve. Terminal type: Exposed-lead Models OMRON Foundation type temperature controller.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 15cm.
Lead wire type: Heat resistive.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON Foundation type temperature controller.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater disconnection, SSR fault detection function: 1 points.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connectioon method can be selected from a screw terminal and a PUSH-IN fastening terminal E5CN-Q2HH03T-WFLK.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsion Village (sold separately) connected to the computer after,
No power connection can be set OMRON E5CN-Q2HH03T-WFLK.
It can be easily set by CS-Thermo (sold separately).