A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 20 cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E5CN-RT.
Ideal for the thermal input devices of Temperature Controllers
E5CN-RT
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V) OMRON E5CN-RT.
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / OMRON E5CN-RT.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV OMRON Foundation type temperature controller.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay OMRON Foundation type temperature controller.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Terminal type: Exposed-lead Models OMRON Foundation type temperature controller.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 15 cm.
Lead wire type: Standard.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temmperature Sensors E5CN-RT.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON E5CN-RT.