Control output: Voltage output.
Auxiliary output: Two.
Communications: --.
Heater burnot: Detection for Single-phase heater.
Event inputs: One.
Power supply voltage: 24 VAC/VDC.
for Connections to HMIs and PLCs.
E5@C-800 Series.
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance.
temperature increases.
Easy connections to a PLC with programless communications.
complete basic functions.
checking alarms, and making settings in a control panel.
Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485 OMRON E5DC-QX2DSM-817.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance
E5DC-QX2DSM-817
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance OMRON E5DC-QX2DSM-817.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set OMRON E5DC-QX2DSM-817.
It can be easily set by CS-Thermo (sold separately). Name: HFU with Programless Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None OMRON Digital Temperature Controller.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, 4 OMRON Digital Temperature Controller.
Communications functions: Port C: RS-422,
From End Unit: Port A: RS-485.
Input type: No input.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application OMRON Digital Temperature Controller.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E5DC-QX2DSM-817.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculaate the PID constants with the step,
response method OMRON E5DC-QX2DSM-817.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.