LK Automation Limited
Home >> Products >> OMRON >> Temperature controller >> Universal temperature controller >> E5EC-TRX4ASM-060 E5 - C series of new products program OMRON E5EC-TRX4ASM-060 Digital temperature controller program

E5EC-TRX4ASM-060 E5 - C series of new products program OMRON E5EC-TRX4ASM-060 Digital temperature controller program

Brand: OMRON
Name: Digital temperature controller program
Model: E5EC-TRX4ASM-060
Size: 48 x 96mm.
Control output 1: relay.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: -.
Communication: -.
Break detection: -.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control.

DIN-sized (48 x 48 mm) Temperature.
Controller with Analog Setting.
Compact, low-cost Temperature Controller.
Incorporates proportional control and reset adjustment function.
Consecutive mounting possible using mounting adapter.
Incorporates a plug-in socket, thus allows to DIN-track and flush mounting OMRON E5EC-TRX4ASM-060. Size: 96 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2:-- E5EC-TRX4ASM-060
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: -.
Event input: 4 points OMRON E5EC-TRX4ASM-060.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply OMRON E5EC-TRX4ASM-060.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications OMRON Digital temperature controller program.
The main body is short, the thickness is only 60mm OMRON Digital temperature controller program.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve OMRON Digital temperature controller program. Protection tube diameter: screw pitch W1/4.
Wire length: 2m.
Core line type: K (CA).
Temperature sensing part of temperature controller.
In the application field of packaging molding machine is widely used,
Further strengthened the high cost models.
Easy to install / replace the structure.
With springs, you can use the active part (E52Z-CA1D-40). Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5EC-TRX4ASM-060.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault


...More relevant models >>>>