Ontology: program type.
Size: 48 x 96mm.
Type: 2 input type.
Control mode: 2 channel standard control /1 channel heating and cooling control /1 channel series control and other functions.
Output (control / transfer) points: 2 points (current + current).
Output (SUB) points: 2 points.
Event entry point: 4.
Serial communication: RS-485.
Can be set up to 32 kinds of procedures.
1 units can be coordinated to run up to 4 channels.
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set.
Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater OMRON E5ER-TCT3DW-FLK.
Event entry point: 4.
Transfer output: transfer output (special terminal)
E5ER-TCT3DW-FLK
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved OMRON E5ER-TCT3DW-FLK.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV OMRON E5ER-TCT3DW-FLK.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault OMRON Program type digital regulator.
Position ratio type. Control output 1: Voltage output.
Control output 2: Relay output OMRON Program type digital regulator.
Auxiliary output: Two.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance OMRON Program type digital regulator.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. Ontology: terminal type, analog input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Fuurther performance improvement E5ER-TCT3DW-FLK.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV OMRON E5ER-TCT3DW-FLK.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.