Home >> Products >> MITSUBISHI >> Inverter >> FR-A700 series inverter >> FR-A720 inverter 3 phase 200V >> FR-A720-075K MITSUBISHI 3 phase 400V converter FR-A720-075K

FR-A720-075K MITSUBISHI 3 phase 400V converter FR-A720-075K

Brand: MITSUBISHI
Name: 3 phase 200V converter
Model: FR-A720-0.75K
MITSUBISHI inverter FR-A720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 0.75KW.
Inverter output for the PWM wave, containing more harmonic.
Frequency conversion power sensor through the input voltage and current signals to exchange sampling,
Sampling value through cable, optical fiber and other transmission systems and digital input frequency conversion power analyzer,
The sampling value of the voltage and current is calculated by the digital input frequency conversion power analyzer,
It can obtain the parameters such as voltage effective value, current effective value, fundamental wave voltage, fundamental current, harmonic voltage, harmonic current, active power, fundamental wave power and harmonic power.

MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 0.4kw.
SLD converter rated current: 4.6A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation MITSUBISHI FR-A720-0.75K.
(rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station FR-A720-0.75K
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same time, used in the control of the external machine.
No external PID controller is used to control the external machine, so the system cost can be reduced MITSUBISHI FR-A720-0.75K. Power: 185kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose MITSUBISHI FR-A720-0.75K. ) Power: 55kw.
Voltage: 400V.
Purpose: high frequency braking resistor.
The braking ability provided by the braking capacity is larger than that provided by the external braking resistor.
Can also be connected without built-in brake transistor inverter MITSUBISHI 3 phase 400V converter.
Three types of discharge resistors are available.
Please select according to the required braking torque. Superior high efficiency IPM motor MITSUBISHI 3 phase 400V converter.
Output power: 2.2kw.
Rated speed: 1500r/min.
Voltage level: 200V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m.
1 inverters can not connect multiple IPM motors at the same time. MITSUBISHI inverter FR-D720S series MITSUBISHI 3 phase 400V converter.
Voltage level: single phase 200V.
Frequency converter capacity: 1.5KW.
VVVF frequency control, vector control frequency conversion, direct torque control is a kind of AC - DC - AC frequency conversion.
The common drawback is that the input power factor is low, the harmonic current is big, and the DC circuit needs large energy storage capacity,
Renewable energy and can not be fed back to the power grid, which can not be carried out in the four quadrant operation. To this end, the matrix type of AC - AC variable frequency arises at the historic moment.
Because the matrix type alternating current frequency saves the intermediate DC link, thereby, the electrolytic capacitor with large volume and high price can be ommitted FR-A720-0.75K.
It can achieve a power factor of L, the input current is sinusoidal and can run in four quadrant, the power density of the system is large.
Although the technology is not yet mature, but still attract a large number of scholars in-depth study MITSUBISHI FR-A720-0.75K.
In fact, the quality is not the indirect control current, flux, but the torque is directly used as the control to achieve.