MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 75KW.
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the motor operating power frequency mode to control the AC motor power control equipment.
The converter is composed of rectifier (AC), filter, inverter (DC), braking unit, driving unit, micro processing unit of the detection unit.
Inverter by the internal IGBT to adjust the output power supply voltage and frequency,
According to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition to the,
Inverter has a lot of protection functions, such as over current, over voltage, overload protection and so on.
MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 5.5kw.
SLD converter rated current: 34A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation MITSUBISHI FR-A740-75K-CHT.
(rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station
FR-A740-75K-CHT
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same time, used in the control of the external machine.
No external PID controller is used to control the external machine, so the system cost can be reduced MITSUBISHI FR-A740-75K-CHT. Power: 560kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose MITSUBISHI FR-A740-75K-CHT. ) MITSUBISHI inverter series: FR-A800.
Voltage level: three phase 400V.
Power: 45kw.
SLD converter rated current: 116A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Mirror like ultra fine processing.
In order to adapt to the new material diversification, the machine adopts the most cutting-edge technology, more than ever more slim hard MITSUBISHI Three phase 200V grade frequency converter.
In order to be able to realize the fine cutting, grinding on the hard and hard material,
The need for high-speed operation has become more and more strong MITSUBISHI Three phase 200V grade frequency converter.
In order to cope with the increasing demand of logistics, every port in the world has a crane in every day.
A container filled with cargo.
We can achieve a new type of inverter products under the conditions of low speed and high torque to achieve smooth cargo handling operations,
Carry on the smooth movement to the heavy MITSUBISHI Three phase 200V grade frequency converter. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 55kw.
SLD converter rated current: 316A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on.
1 pumps driven by parallel connection of tthe pump machine, in addition to the pump for power frequency drive FR-A740-75K-CHT.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted too a more intuitive display unit% units MITSUBISHI FR-A740-75K-CHT.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display.