LK Automation Limited
Home >> Products >> MITSUBISHI >> Inverter >> Inverter accessories >> FR-A8AP 3 phase 200V converter MITSUBISHI FR-A8AP

FR-A8AP 3 phase 200V converter MITSUBISHI FR-A8AP

Brand: MITSUBISHI
Name: Directional control /PLG module
Model: FR-A8AP
Can use the encoder to perform vector control.
Combined use of the position detector (PLG) with the position of the main shaft of the working machine,
Can be carried out on the position of the spindle stop (directional) control.
The speed is kept constant through feedback motor rotation speed.

Power: 75kw.
Voltage: 200V.
Sine wave filter.
The voltage and current of the motor can be adjusted to a sine wave.
The sine wave filter is installed to the output terminal of the inverter.
Applicable to FR-A820-03800 (75K) above and FR-A840-02160 (75K) and above frequency converter.
Sine wave filter is equivalent to the operational characteristics of the sine wave power driver, can provide the following benefits MITSUBISHI FR-A8AP FR-A8AP
Low noise.
No surge current.
Reduce motor loss (standard motor). Superior high efficiency IPM motor.
Output power: 2.2kw.
Rated speed: 1500r/min.
Voltage level: 400V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m MITSUBISHI FR-A8AP.
1 inverters can not connect multiple IPM motors at the same time. Superior high efficiency IPM motor.
Output power: 22kw.
Rated speed: 1500r/min.
Voltage level: 200V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m.
1 inverters can not connect multiple IPM motors at the same time. MITSUBISHI inverter FR-F740 series MITSUBISHI FR-A8AP.
Voltage level: three phase 400V.
Frequency converter capacity: 250KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor MITSUBISHI 3 phase 200V converter MITSUBISHI 3 phase 200V converter.
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the motor MITSUBISHI 3 phase 200V converter.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity. MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 355KW.
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the motor operating power frequency mode to control the AC motor power control equipment.
The converter is composed of rectifier (AC), filter, inverter (DC), braking unit, driving unit, micro processing unit of the detecction unit FR-A8AP.
Inverter by the internal IGBT to adjust the output power supply voltage and frequency,
According to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy savving, speed control, in addition to the,
Inverter has a lot of protection functions, such as over current, over voltage, overload protection and so on MITSUBISHI FR-A8AP.


...More relevant models >>>>