LK Automation Limited
Home >> Products >> OMRON >> Relay >> General relay >> Relay for control cabinet >> G2AK-234A OMRON G2AK-234A

G2AK-234A OMRON G2AK-234A

Brand: OMRON
Name: Latching Relay
Model: G2AK-234A
Contact form: DPDT.
Classification: Fully sealed model.
Plug-in terminals.
Magnetic Latching Version of G2A Ideal for.
Sequence Control.
Double-winding latch system with continuous rating.
Terminals pulled from the respective junctions between the,
built-in diodes and set and reset coils allow the built-in diodes to,
be externally connected for coil surge absorption.
Excellent vibration/shock resistance with minimal secular,
decrease in latching power.
Easy monitoring of ON/OFF operation due to the built-in,
operation indicator mechanism.
Same outline dimensions as the standard models of G2A.

Structure: Relays with Plug-in Terminals, With operation indicators.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act.
Number of poles: 2 Bifurcated.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety OMRON G2AK-234A.
standards and with the Electrical Appliances and,
Material Safety Act G2AK-234A
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup also includes models that are compliant,
with the LR and VDE safety standards.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 100/110 VDC) OMRON G2AK-234A.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC). Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes OMRON G2AK-234A.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 35 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer OMRON Latching Relay.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters OMRON Latching Relay.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable) OMRON Latching Relay.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: DC load.
Zero cross function: --.
Rated input voltage: AC 110V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminalss G2AK-234A. ).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs OMRON G2AK-234A.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange.


...More relevant models >>>>