Number of elements: 3.
Insulation method: Photocoupler.
Rated supply voltage: 100 to 240 VAC.
Applicable motor: 0.75 kW (4.8 A), 200 to 220 VAC.
and Achieve Harmonized Protection with Thermal.
Overload Relays.
Certified for UL and CSA.
Mount with screws or to DIN tracks.
Compact monoblock construction (W: 80 × H: 100 × D: 100 mm).
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.
Two-element models added to series.
Classification: electric arc barrier.Classification: Models with built-in operation indicators.
Rated voltage: Standard products, 12, 24, 100/110, 110/120, 200/220,
or 220/240 VAC, 12, 24, 48, or 100/110 VDC; Made-to-order items, --.
New Latching Levers for Circuit Checking.
Added to Our Best-selling OMRON G3J-205BL AC100-240.
MY General-purpose Relays.
Now lead-free to protect the environment
G3J-205BL AC100-240
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them.
MY(S) models with latching levers added for,
easier circuit checking. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 75 A at 200 to 480 VAC (See note 2 OMRON G3J-205BL AC100-240. ).
Rated input voltage: 100 to 240 VAC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B) OMRON G3J-205BL AC100-240.
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Input terminals: Screwless clamp terminals (detachable) OMRON Simple Solid State Contactors.
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection) OMRON Simple Solid State Contactors.
Applicable load (See note.): 2 to 25 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps OMRON Simple Solid State Contactors.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heatters G3J-205BL AC100-240.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) OMRON G3J-205BL AC100-240.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.